Technolec

WAC-M300 SERIES

L2 industrial wireless access controller for TAP-M310R Series, 0 to 50°C operating temperature
wac-m300-series
Supports Layer 2 roaming
Sub-50 ms controller-based Turbo Roaming for Wi-Fi 6 capable TAP rail devices
Intuitive portal interface for centralized device management and wireless network maintenance
Device-level redundancy via hot standby controller

Ethernet Interface

  • 10/100/1000BaseT(X) Ports (RJ45 connector): 2Port 1: Communications port for WAC/HAPort 2: Reserved
  • Standards: IEEE 802.11i for Wireless Security IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3ab for 1000BaseT(X) IEEE 802.1X for authentication

Ethernet Software Features

  • Management: IPv4 SNMPv1/v2c/v3 Syslog TCP/IP Telnet Web Console Wireless Search Utility MXconfig MXview One
  • Security: HTTPS/SSL RADIUS SSH
  • Time Management: NTP Client

Serial Interface

  • Console Port: RS-232 ports x 1 (DB9 male)
  • Flow Control: RTS/CTS, XON/XOFF
  • Parity: None, Even, Odd, Space, Mark

Serial Signals

  • RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

Wireless Access Control

  • Controller Failover Mode: 1-on-1 hot backup
  • Handover Time: 50 ms
  • Roaming Support: Turbo Roaming (L2) with inter-controller capabilities
  • WLAN Products Supported: Layer 2 networks: Up to 190 clients roaming between 400 APs

Supported Devices

  • TAP Products: TAP-M310R Series

Power Parameters

  • Input Current: 1.2 A @ 100 VAC
  • Input Voltage: 100 to 240 VAC
  • No. of Power Inputs: 2
  • Operating Voltage: 100 to 240 VAC

Physical Characteristics

  • Housing: Metal
  • Dimensions (without ears): 304 x 440 x 44 mm (11.97 x 17.32 x 1.73 in)
  • Weight: 5,480 g (12.08 lb)
  • Installation: 19-inch rack mounting

Environmental Limits

  • Operating Temperature: 0 to 50°C (32 to 122°F)
  • Storage Temperature (package included): -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity: 5 to 95% (non-condensing)

Standards and Certifications

  • Safety: UL 62368-1 EN 62368-1 IEC 62368-1
  • EMC: EN 55032/35 EN 61000-6-2/-6-4
  • EMI: CISPR 32, FCC Part 15B Class A
  • EMS: IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1000 MHz: 20 V/m IEC 61000-4-3 RS: 1400 MHz to 2000 MHz: 10 V/m IEC 61000-4-3 RS: 2000 MHz to 2700 MHz: 5 V/m IEC 61000-4-3 RS: 5100 MHz to 6000 MHz: 3 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF: 100 A/m

Declaration

  • Green Product: RoHS, CRoHS, WEEE

MTBF

  • Time: 770,346 hrs
  • Standards: Telcordia Standard SR-332

Warranty

  • Warranty Period: 5 years
  • Details: See www.moxa.com/warranty

Available Models

Model No. Description Quantity
WAC-M300 L2 industrial wireless access controller for TAP-M310R Series, 0 to 50°C operating temperature