EDF-G1002-BP SERIES
Industrial next-gen LAN firewall with 2 10/100/1000BaseT(X) ports, 1 Ethernet-based management port, Intrusion Prevention System (IPS), Deep Packet Inspection (DPI), Gen3 bypass, centralized management through MXsecurity, -10 to 60°C operating temperature
Input/Output Interface
- Alarm Contact Channels: Resistive load: 1 A @ 24 VDC
- Buttons: Reset button
- Digital Input Channels: +13 to +30 V for state 1 -30 to +3 V for state 0 Max. input current: 8 mA
Ethernet Interface
- 10/100/1000BaseT(X) Ports (RJ45 connector): 3 (2 x LAN ports, 1 x MGMT port)
- Standards: IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3ab for 1000BaseT(X) IEEE 802.3x for flow control
Ethernet Software Features
- Management: DDNS Web Console (HTTP/HTTPS) LLDP SNMPv1/v2c/v3 Telnet TFTP SSH
- Concurrent Connections: Max. 120K (based on RFC 3511)
- Connections Per Second: Max. 6K (based on RFC 3511)
- Security: Secure Boot RADIUS Trust access control TACACS+ SCP SFTP NTP authentication Syslog authentication
- Time Management: NTP Server/Client SNTP
LED Interface
- LED Indicators: PWR1, PWR2, STATE, BYPASS, USB
DoS and DDoS Protection
- Technology: ARP-Flood FIN Scan ICMP Flood TCP Sessions Without SYN NMAP-ID Scan NMAP-Xmas Scan Null Scan SYN/FIN Scan SYN/RST Scan SYN-Flood Xmas Scan UDP Flood
Firewall
- Throughput: Firewall: Max. 80K packets per second / 1000 Mbps (based on RFC 2544)IPS: Max. 40K packets per second / 500 Mbps (based on RFC 2544)
- Filter: DDoS Ethernet protocols ICMP IP address MAC address Ports
- Intrusion Prevention System: Enabled by default. IPS pattern update functionality requires an additional license.
- Deep Packet Inspection: Modbus TCP Modbus UDP DNP3 IEC 60870-5-104 IEC 61850 MMS EtherNet/IP MELSEC Omron FINS OPC UA Siemens S7 Comm. Siemens S7 Comm. Plus Additional protocols will be supported through future firmware updates.
Real-time Firewall Event Log
- Event Type: Firewall events Protocol DPI and IDS/IPS events
- Media: Syslog server Local storage SNMP Trap
Serial Interface
- Console Port: RS-232 (TxD, RxD, GND), 3-pin (115200, n, 8, 1)
- Connector: USB Type-C
Power Parameters
- Connector: Removable terminal block
- Operating Voltage: 9.6 to 60 VDC
- Input Voltage: 12/24/48 VDC (DNV certified) Redundant dual inputs
- Input Current: 0.69 A (max)
- Reverse Polarity Protection: Supported
Physical Characteristics
- Housing: Metal
- Dimensions: 35 x 125 x 100 mm (1,38 x 4.92 x 3.94 in)
- Weight: 385 g (0.85 lb)
- Installation: DIN-rail mounting (DNV certified) Wall mounting (DNV certified)
Environmental Limits
- Operating Temperature: -10 to 60°C (14 to 140°F)
- Storage Temperature (package included): -40 to 85°C (-40 to 185°F)
- Ambient Relative Humidity: 5 to 95% (non-condensing)
Standards and Certifications
- Safety: IEC 62368-1 UL 62368-1
- EMC: EN 55032/35
- EMI: CISPR 32, FCC Part 15B Class A
- EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF
- Railway: EN 50121-4
- Traffic Control: NEMA TS2
- Maritime: DNV
- Shock: IEC 60068-2-27
- Freefall: IEC 60068-2-32
- Vibration: IEC 60068-2-6
- Hazardous Locations: ATEX Class I Division 2 IECEx
MTBF
- Time: 2,929,641 hrs
- Standards: Telcordia (Bellcore), GB
Warranty
- Warranty Period: 5 years
- Details: See www.moxa.com/warranty