Technolec

EDF-G1002-BP SERIES

Industrial next-gen LAN firewall with 2 10/100/1000BaseT(X) ports, 1 Ethernet-based management port, Intrusion Prevention System (IPS), Deep Packet Inspection (DPI), Gen3 bypass, centralized management through MXsecurity, -10 to 60°C operating temperature
edf-g1002-bp-series

Input/Output Interface

  • Alarm Contact Channels: Resistive load: 1 A @ 24 VDC
  • Buttons: Reset button
  • Digital Input Channels: +13 to +30 V for state 1 -30 to +3 V for state 0 Max. input current: 8 mA

Ethernet Interface

  • 10/100/1000BaseT(X) Ports (RJ45 connector): 3 (2 x LAN ports, 1 x MGMT port)
  • Standards: IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3ab for 1000BaseT(X) IEEE 802.3x for flow control

Ethernet Software Features

  • Management: DDNS Web Console (HTTP/HTTPS) LLDP SNMPv1/v2c/v3 Telnet TFTP SSH
  • Concurrent Connections: Max. 120K (based on RFC 3511)
  • Connections Per Second: Max. 6K (based on RFC 3511)
  • Security: Secure Boot RADIUS Trust access control TACACS+ SCP SFTP NTP authentication Syslog authentication
  • Time Management: NTP Server/Client SNTP

LED Interface

  • LED Indicators: PWR1, PWR2, STATE, BYPASS, USB

DoS and DDoS Protection

  • Technology: ARP-Flood FIN Scan ICMP Flood TCP Sessions Without SYN NMAP-ID Scan NMAP-Xmas Scan Null Scan SYN/FIN Scan SYN/RST Scan SYN-Flood Xmas Scan UDP Flood

Firewall

  • Throughput: Firewall: Max. 80K packets per second / 1000 Mbps (based on RFC 2544)IPS: Max. 40K packets per second / 500 Mbps (based on RFC 2544)
  • Filter: DDoS Ethernet protocols ICMP IP address MAC address Ports
  • Intrusion Prevention System: Enabled by default. IPS pattern update functionality requires an additional license.
  • Deep Packet Inspection: Modbus TCP Modbus UDP DNP3 IEC 60870-5-104 IEC 61850 MMS EtherNet/IP MELSEC Omron FINS OPC UA Siemens S7 Comm. Siemens S7 Comm. Plus Additional protocols will be supported through future firmware updates.

Real-time Firewall Event Log

  • Event Type: Firewall events Protocol DPI and IDS/IPS events
  • Media: Syslog server Local storage SNMP Trap

Serial Interface

  • Console Port: RS-232 (TxD, RxD, GND), 3-pin (115200, n, 8, 1)
  • Connector: USB Type-C

Power Parameters

  • Connector: Removable terminal block
  • Operating Voltage: 9.6 to 60 VDC
  • Input Voltage: 12/24/48 VDC (DNV certified) Redundant dual inputs
  • Input Current: 0.69 A (max)
  • Reverse Polarity Protection: Supported

Physical Characteristics

  • Housing: Metal
  • Dimensions: 35 x 125 x 100 mm (1,38 x 4.92 x 3.94 in)
  • Weight: 385 g (0.85 lb)
  • Installation: DIN-rail mounting (DNV certified) Wall mounting (DNV certified)

Environmental Limits

  • Operating Temperature: -10 to 60°C (14 to 140°F)
  • Storage Temperature (package included): -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity: 5 to 95% (non-condensing)

Standards and Certifications

  • Safety: IEC 62368-1 UL 62368-1
  • EMC: EN 55032/35
  • EMI: CISPR 32, FCC Part 15B Class A
  • EMS: IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 PFMF
  • Railway: EN 50121-4
  • Traffic Control: NEMA TS2
  • Maritime: DNV
  • Shock: IEC 60068-2-27
  • Freefall: IEC 60068-2-32
  • Vibration: IEC 60068-2-6
  • Hazardous Locations: ATEX Class I Division 2 IECEx

MTBF

  • Time: 2,929,641 hrs
  • Standards: Telcordia (Bellcore), GB

Warranty

  • Warranty Period: 5 years
  • Details: See www.moxa.com/warranty