Technolec

PT-G503-PHR-PTP SERIES

IEC 61850-3 and IEC 62439-3 full Gigabit managed redundancy box, with 3 10/100/1000BaseT(X) ports or 100/1000Base SFP ports, 1 10/100/1000BaseT(X) Ethernet console port, 1 isolated dual power supply(88 to 300 VDC or 85 to 264 VAC), -40 to 85°C operating temperature

  • • Technology: Standards
  • IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseX: • Software Features
  • Management: IPv4/IPv6, PRP/HSR, SNMPv1/v2c/v3, DHCP Client, BootP, SMTP, RARP, HTTP, Telnet, LLDP, Flow Control, Back Pressure Flow Control, SNMP Inform, Port Mirror, Fiber Check, Syslog, RMON
  • Filter: Multicast Filter Behavior
  • Redundancy Protocols: PRP/HSR, RSTP Transparent
  • Security: RADIUS, TACACS+, Trusted Access Control, Authentication Certificate (SSL Certificate, SSH Key Regenerate)
  • Time Management: SNTP, NTP Server/Client, IEEE 1588v2 PTP
  • Industrial Protocols: Modbus/TCP
  • MIB: IEC 62439-3 MIB
  • Power Substation: MMS
  • • Interface: Gigabit Ethernet
  • 3 x 10/100/1000BaseT(X) ports or 100/1000BaseSFP combo ports: Console Port
  • Ethernet console (10/100/1000 Mbps RJ45), USB-serial console (Type B connector): Storage Port
  • USB storage (Type A connector for ABC-02-USB): Alarm Contact
  • 1 relay output with current carrying capacity of 1 A @ 24 VDC: Digital Inputs
  • 1 input with the same ground, but electrically isolated from the electronics• +13 to +30 V for state “1” • -30 to +3 V for state “0” • Max. input current: 8 mA: • Power Requirements
  • Input Voltage: • WV: 24/48 VDC • HV: 110/220 VDC/VAC
  • Operating Voltage: • WV: 18 to 72 VDC • HV: 88 to 300 VDC, 85 to 264 VAC
  • Input Current: • Max. 0.660/0.360 A @ 24/48 VDC • Max. 0.150/0.080 A @ 110/220 VDC • Max. 0.260/0.170 A @ 110/220 VAC
  • Overload Current Protection: Present
  • Connection: 5-pin terminal block
  • Reverse Polarity Protection: Present
  • • Physical Characteristics: Housing
  • Aluminum alloy: IP Rating
  • IP40 protection: Dimensions
  • 80 x 160 x 110 mm (3.15 x 6.30 x 4.33 in): Weight
  • 1210 g (2.69 lb): Installation
  • DIN-rail mounting: • Environmental Limits
  • Operating Temperature: -40 to 85°C (-40 to 185°F)
  • Storage Temperature: -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity: 5 to 95% (non-condensing)
  • • Standards and Certifications: High Availability Automation Networks
  • IEC 62439-3: Safety
  • UL 508: EMI
  • FCC Part 15 Subpart B Class A, EN 55032 Class A: EMS
  • IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 35 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV IEC 61000-4-5 Surge: Power: 4 kV; Signal: 4 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 IEC 61000-4-11: Electrical Substation
  • IEC 61850-3, IEEE 1613: Rail Traffic
  • EN 50121-4: • MTBF (mean time between failures)
  • Time: PT-G503-PHR-PTP-WV:440,857 hrs PT-G503-PHR-PTP-HV:566,844 hrs
  • Standard: Telcordia TR/SR
  • • Warranty: Warranty Period
  • 5 years: Details