Technolec

MD-224 SERIES

24-inch display, 300-nit LCD without touch, VGA/DVI-D input, -15 to 55°C operating temperature, dual AC/DC power inputs, IP54 in front
md-224-series
24-inch display, 16:9 aspect ratio
300-nit or sunlight-readable 1000-nit LED backlight
Color calibrated for ECDIS compliance (available by CTOS)
Full range dimming, 0 to 100%
SavvyTouch display controls
Built-in RS-232/422/485 interfaces
Dual power supplies (AC & DC)
IP54-rated front panel (IP66 available by request)

Display

  • Aspect Ratio: 16:9
  • Contrast Ratio: 5,000:1
  • Max. No. of Colors: 16.7M (8-bit/color)
  • Panel Size: 24-inch viewable image
  • Panel Type: MVA
  • Pixels: 1920 x 1080
  • Response Time: 25 ms (gray to gray)
  • Viewing Angles: 178°/178°
  • Light Intensity (Brightness): 300 cd/m2

Computer Interface

  • Serial Ports: RS-232 ports x 1 (DB9 male) RS-232/422/485 ports x 1, software selectable (terminal block)
  • Video Input: DVI-D x 1, 29-pin DVI-D connectors (female) VGA x 1, 15-pin D-sub connector (female)

Touch Function

  • Touch Type: None

Serial Interface

  • Baudrate: 50 bps to 115.2 kbps
  • Data Bits: 5, 6, 7, 8
  • Flow Control: RTS/CTS, XON/XOFF, ADDC® (automatic data direction control) for RS-485, RTS Toggle (RS-232 only)
  • Parity: None, Even, Odd, Space, Mark
  • Stop Bits: 1, 1.5, 2

Serial Signals

  • RS-232: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
  • RS-422: Tx+, Tx-, Rx+, Rx-, GND
  • RS-485-2w: Data+, Data-, GND
  • RS-485-4w: Tx+, Tx-, Rx+, Rx-, GND

Power Parameters

  • Input Voltage: 100 to 240 VAC 24 VDC (18 to 30 V)
  • Power Consumption: 40 W (max.)

Physical Characteristics

  • Housing: Metal
  • Dimensions: 595 x 393 x 75 mm (23.43 x 15.47 x 2.95 in)
  • Weight: 9,570 g (21.10 lb)
  • Installation: Desktop Panel mounting VESA mounting
  • IP Rating: IP54, front IP22, rear

Environmental Limits

  • Operating Temperature: -15 to 55°C (5 to 131°F)
  • Storage Temperature (package included): -20 to 60°C (-4 to 140°F)
  • Ambient Relative Humidity: 5 to 95% (non-condensing)

Standards and Certifications

  • EMC: EN 55032/24
  • EMI: CISPR 32, FCC Part 15B Class A
  • EMS: IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m IEC 61000-4-4 EFT: Power: 1 kV; Signal: 0.5 kV IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV IEC 61000-4-6 CS: 1k V
  • Maritime: ABS CCS IEC 60945 DNV
  • Safety: UL 60950-1

Warranty

  • Warranty Period: LCD: 1 year System: 3 years
  • Details: See www.moxa.com/warranty