Technolec

ISD-1210-T/ISD-1230-T SERIES

4 data line advanced surge protector, RS-232, 20 kV surge protection, -40 to 85°C operating temperature

Data Line Surge Protection

  • Maximum Power Protection: 5000 watts
  • Number of Protected Lines: 4
  • Surge Capacity: 20 kV, 8/20 μs impulse per line
  • Working Voltage: ISD-1210-T: 15 V ISD-1230-T: 5 V
  • Maximum Load Current: 0.4 A (20°C), 0.13 A (85°C)
  • Response Time: < 1 ns
  • Protection Mode: Line to line, line to ground
  • Protection Rating: IP30
  • Bandwidth: 10 MHz loss < 1 dB

Connectors

  • ISD-1110-T: Data in: DB9 male Data out: DB9 female
  • ISD-1130-T: Data in: Terminal block Data out: Terminal block
  • ISD-1210-T/1230-T: Data in: Terminal block Data out: Terminal block

Physical Characteristics

  • Housing: Metal
  • Dimensions: ISD-1210-T: 95 x 53 x 25 mm (3.74 x 2.01 x 0.98 in) ISD-1230-T: 95 x 53 x 25 mm (3.74 x 2.01 x 0.98 in)
  • Weight: Product only ISD-1210-T: 214 g (0.47 lb) ISD-1230-T: 212 g (0.46 lb) Packaged ISD-1210-T: 276 g (0.61 lb) ISD-1230-T: 274 g

<p>Environmental Limits <br><font color="#ff0000" size="1">Note: Please contact Moxa if you require products guaranteed to function properly at higher altitudes.</font></p>

  • Operating Temperature: -40 to 85°C (-40 to 185°F)
  • Storage Temperature: -40 to 85°C (-40 to 185°F)
  • Ambient Relative Humidity: 95% max, non-condensing

Standards and Certifications

  • EMS: IEC 61643-21 C2 (20 kV 1.2/50, 10 kA 8/20)

Warranty and RMA Policy

  • Warranty Period: 5 years (limited to 1-time use)
  • Warranty Details: See www.moxa.com/warranty Note: ISD products will only be repaired once within 5 years of purchase. After the first repair, the product’s warranty will no longer be valid.
  • RMA Policy: Moxa does not provide RMA service for ISD products whose PCB board was destroyed by a surge. Note: Be sure to purchase the ISD product with maximum surge protection suitable for your environment.